Ac ke compressors ko direct kaise chalae

Aaj ham sikhenge ki AC ke Compressor ko direct kaise chalae using Capacitor


Bahut sare ac technician ko nahi pata ki compressor ko direct kaise chalae to aaj ham un hi logo ke lie ye post likh rahe hai Agar apko pehle se pata hai ki compressor ko direct kaise chalaya jata hai to aap ko is article ko padhne ki koi jarurat nahi hai - ( is website pe me kisi ka time barbad nhi karna chahta )

Step 1 >>

  • Sabse pahle apko kisi bhi compressor ke Terminal se CSR ( Common Starting Running ) nikalna hoga Agar aap CSR nikalna jante hai tab to apke lie asan hai aur kai sare compressors pe CSR likha hota hai ya kisi pe likha nahi bhi hota hai 



  • ( Agar kisi Compressors pe CSR na likha ho to wo kaise nikale janne ke lie comment kare me uske bare me details me batane ki kosis karunga )

Step 2 >>

  • Ab CSR nikalne ke baad apko ek ( Running ) capacitor chahiye hoga
  • Ho sake to compressor ke capacity ke hisab se aap capacitor use karen 



Capacitors Type >> 

  1. Single Run Round  ( 35, 40, 45....MFD ) (Compressor Only)
  2. Dual Run Round ( 35+2, 40+4, 45+5...MFD ) (Compressor + Fan)

Step 3 >>

  • Ab compressor ko capacitor se conect karte hai 
  • Sabse pehle compressor ke Running Aur Starting Terminal me ek ek wire conect kar lena hai uske baad comressor ke starting wire ko capacitor ke C terminal Me conect kar dena hai aur Compressor ke  Running wire ko Capacitor ke H terminal me jor dena hai 

Step 4 >> 

  • Ab compressor ko current dena hai
  • Compressor ko current dene ke lie apko Compressor ke common terminal me phase dena hai aur capacitor ke C me neutral dena hai 

Step 5 >>

  • Ab compressor ko current ( 220 volt AC ) dena hai ab compressor start karna hai aur AMPERE METER laga lena hai aur dekhna hai ki ampere normal chal raha hai ya nahi kai baar RUNNING aur STARTING wire ulte hone pe Ampere jyada lene lagte hai - tab apko capacitor pe lage compressor ke running aur starting wire palatne padenge yani running ko C pe conect aur starting ko H pe conect karna hoga phir compressor ko start kare phir ampere meter laga ke dekhe compressor normal ampere pe chalega

Explain - is project me hamne jo capictor use kiya wo sirf compressor chalane ke lie kiya hai agar ham fan chalana chahte hai to ham dual run round capacitor use kar sakte hai 


>> Compressor ko kaise check karte hai ki compressor sahi hai ya kharab janne ke lie comment kare aur han is post ko apne doston ke sath share jarur kare dhanyawad

Agar ye post pasand aai ho ya aise hi post ke lie hame comment karke jarur batae 

www.technicalinformer.in

0/Post a Comment/Comments

हमे Comment कर के Motivate करें

Previous Post Next Post